PANAMAX MR4000


Panamax’s MR Family of products offers several layers of surge protection. Panamax’s patented Automatic Voltage Monitoring (AVM) technology continuously monitors the incoming power. In case of an undervoltage or brownout (too little electricity) or an overvoltage (too much electricity) a flashing red lightning bolt will be displayed and power to the equipment is automatically turned off. When voltage returns to a safe level, power to the equipment is automatically reconnected.

The other layer of surge protection Panamax offers is our exclusive Protect or Disconnect™ technology. This ultra fast protection circuitry completely protects your equipment from surges such as lightning. When overwhelmed with extreme catastrophic events, Panamax permanently disconnects AC power to equipment. All Panamax products offer this core protection technology.

AC Protection

Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)400V
Under-voltage shutoff95V ±2V
Thermal FusingYes
Single Pulse Energy Dissipation1350 Joules
Response Time< 1ns
Protection ModesL-N, L-G, N-G
Protect or Disconnect CircuitryYes
Peak Impulse Current52,000 Amps
Over-voltage shutoff140V ±4V
Maximum Current Rating15A (1800W)
Line Voltage120V, 50/60Hz
Initial Clamping Level200V Peak, 141VRMS
Automatic Voltage Monitoring CircuitYes

Premium Level 2 Noise Filtration

-30dB min. @ 100kHz
-55dB min. @ 250kHz
-45dB min. @ 500kHz
Max filtration: -60dB @ 300kHz

General

Weight6.5 lbs.
Dimensions6”l x 17”w x 1.75”h, 2.19”h with feet

LAN Protection

Wires Protected8-Wires
JacksRJ-45
Compatibility10/100bT
Clamping Level50V

Universal Coax Protection

ShieldedYes
Insertion Loss< 0.5 dB
HD 1080 i/p ReadyYes
Frequency Range0 MHz – 2.2 GHz
ConnectionsFemale “F”, Gold Plated
Clamping Level75V
BidirectionalYes
Dimensões: (A x L x P): 152mm x 431mm x 444mm

Sobre Carlos Avelar

Diretor de Infra-estrutura de TI do Tribunal Regional do Trabalho - 3a. Região (1989 - 2,012); - Informatizou a Segunda Instância do TRT 3ª Região e Gabinetes de Desembargadores; - Responsável pela Implantação da Rede de Computadores no TRT; - Interligação de Todas as Varas da Justiça do Trabalho (Capital e Interior); - Desenvolveu e coordenou a Implantação da TV-TRT3 com a Transmissão ao vivo das Sessões de Julgamento; - Diretor Responsável pela Implantação do CPD de alta performance e redundância total na Justiça do Trabalho - Iniciou ao processo de Implantação do Plano da Segurança da Informação no âmbito da JT em Minas Gerais; - Disponibilizou a Infra-Estrutura para o Sistema de Sustentação Oral à Distância nas Varas do Trabalho do Interior por meio de Vídeo Conferência. Empresário sócio de AVELAR HD home cinema